1. With environmental resistance, anti-ultraviolet attenuation, good electrical insulation, low smoke, low toxicity, high fire resistance, high conductivity and other characteristics.

2. Our company set up a professional research team, and strive to minimize the power loss of photovoltaic cables, and improve its outdoor environment adaptability, we insist on using the best products and services, to give customers the best shopping and use experience.

    PRODUCT FEATURES

    1. Environmental resistance: It can withstand outdoor, ultraviolet, temperature changes and adverse weather conditions to ensure reliability in various climatic conditions.
    2. Anti-ultraviolet attenuation: It has anti-ultraviolet attenuation characteristics to extend the service life of the cable.
    3. Good electrical insulation: Ensure that the cable can still provide safe power transmission under high voltage, reducing the risk of electric shock and fire.
    4. Low smoke combustion: Low smoke zero halogen material produce less smoke in the event of a fire, which helps to improve the safety of personnel evacuation.
    5. Low toxicity:Low smoke zero halogen material usually have low toxicity, even when burning, they produce less toxic gas, helping to reduce the risk of toxicity in a fire.
    6. High fire resistance: Low smoke zero halogen material usually have high fire resistance, which can protect the insulation material inside the cable in a fire and prevent the spread of fire.
    7. High conductivity: It can provide efficient power transmission and reduce resistance loss.

    SCOPE OF USE

    Photovoltaic cable.

    Test items and standards

    Properties of halogen-free low smoke flame retardant thermoplastic polyolefin insulating materials and sheathing materials.

    Inspection item

    Unit

    Requirements

    WDZ-Y-J70

    WDZ-Y-H70

    WDZ-Y-H90

    1

    Tensile strength

    MPa

    ≥10. 0

    ≥10. 0

    ≥10. 0

    2

    Elongation at break

    %

    ≥160

    ≥160

    ≥160

    3

    Air aging chamber

     

     

     

     

    Aging temperature

    100±2

    100±2

    110±2

    Aging time

    h

    168

    168

    240

    Maximum rate of change of tensile strength

    %

    ±25

    ±25

    ±25

    Maximum rate of change of elongation at break

    %

    ±25

    ±25

    ±25

    4

    Thermal deformation

     

     

     

     

    Test temperature

    90±2

    90±2

    90±2

    Experimental result

    %

    ≤50

    ≤50

    ≤50

    5

    20℃ volume resistivity

    Ω · m

    ≥1. 0×1012

    ≥1. 0×1010

    ≥1. 0×1010

    6

    Volume resistivity at operating temperature

     

     

     

     

    Test temperature

    70±1

    Volume resistivity

    Ω · m

    2. 0×108

    7

    Dielectric strength

    MV/m

    20

    18

    18

    8

    Heat shock test

     

     

     

     

    Test temperature

    130±3

    130±3

    130±3

    Test time

    %

    1

    1

    1

    Experimental result

    No cracking

    No cracking

    No cracking

    9

    Impact embrittlement temperature

     

     

     

     

    Test temperature

    -25

    -25

    -25

    Experimental result

    Number

    ≤15/30

    ≤15/30

    ≤15/30

    10

    Ozone resistance test

     

     

     

     

    Test temperature

    25±2

    25±2

    Experiment time

    h

    24

    24

    Ozone concentration

    ppm

    250~300

    250~300

    Experimental result

    No cracking

    No cracking

    11

    Hot water immersion test

     

     

     

     

    Test temperature

    70±2

    70±2

    Experiment time

    h

    168

    168

    Maximum rate of change of tensile strength

    %

    ±30

    ±30

    Maximum rate of change of elongation at break

    %

    ±35

    ±35

    12

    Oxygen index

    %

    28

    30

    30

    13

    Smoke density

     

     

     

     

    flameless

    ≤350

    ≤350

    ≤350

    flaming

    ≤100

    ≤100

    ≤100

    14

    Combustion releases gas acidity

     

     

     

     

    HCI and HBr content

    %

    ≤0.5

    ≤0.5

    ≤0.5

    HF content

    %

    ≤0.1

    ≤0.1

    ≤0.1

    pH value

    4.3

    4.3

    4.3

    Electric conductivity

    μS/mm

    ≤10

    ≤10

    ≤10

    15

    Material smoke toxicity hazards

    According to the application requirements of the product, negotiated by the supply and demand parties.